TM 9–2350–311–20–2
8–6
8–1
WIRING HARNESS AND CABLE REPAIR — CONTINUED
d.
Female-Type Panel Mounting Receptacle with Ridged Locking Nut
1
Disassembly
(a)
Unscrew nut (1) from shell (2) and slide back on cable leads (3).
(b)
Slide grommet (4) back on cable leads (3).
(c)
Push socket contacts (5) out through rear of insert (6) with pin extractor.
(d)
Slide insert (6) out through rear of shell (2).
(e)
Unsolder cable leads (3) from solder wells of socket contacts (5).
2
Assembly
(a)
Strip cable insulation equal to depth of solder wells of socket contacts (5).
(b)
Slide nut (1) over cable leads (3).
(c)
Slide grommet (4) over cable leads (3).
NOTE
Use rosin core solder only. For soldering instructions, refer to para 2–16.
(d)
Insert cable leads (3) into solder wells of socket contacts (5) and solder.
(e)
Push insert (6) into shell (2) from rear until seated. Groove (7) in insert (6) must be alined with guide in
shell (2) to ensure proper fit.
(f)
Push socket contacts (5) into insert (6) from rear until seated.
(g)
Push grommet (4) down cable leads (3) and over solder wells of socket contacts (5).
(h)
Screw nut (1) onto shell (2).
(i)
Tape wire as required.
2
6
5
3
1
4
7