TM 9–2350–311–20–2
8–11
j.
Male-Type Cable Connector with Washer
1
Disassembly
Cut and discard connector.
2
Assembly
(a)
Strip cable insulation equal to depth of terminal (1) well.
(b)
Slide shell (2) over cable (3).
(c)
Insert cable (3) into terminal (1) well and crimp.
(d)
Place C-washer (4) over cable (3) at crimped junction and slide shell (2) over C-washer and terminal
(1).
3
2
4
1
k.
Female-Type Cable Connector with Sleeve
1
Disassembly
Cut and discard connector.
2
Assembly
(a)
Strip cable insulation approximately 1/8 inch (3.2 mm).
(b)
Slide shell (1) and sleeve (2) over cable (3).
(c)
Place cable (3) in cylinder end of terminal (4) and crimp.
(d)
Slide shell (1) and sleeve (2) over terminal (4).
3
1
2
4