TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 434 of 828

TM 9–2350–311–20–2
8–10
8–1
WIRING HARNESS AND CABLE REPAIR — CONTINUED
h.
Terminal-Type Cable Connectors
1
Disassembly
Cut and discard connector.
2
Assembly
(a)
Strip cable insulation equal to depth of terminal (1) well.
(b)
Slide insulator (2) over cable (3).
(c)
Insert cable (3) into terminal (1) well and crimp.
(d)
Slide insulator (2) over crimped end of terminal (1).
3
2
1
i.
Female-Type Cable Connector with Washer
1
Disassembly
Cut and discard connector.
2
Assembly
(a)
Strip cable insulation approximately 1/8 inch (3.2 mm).
(b)
Slide shell (1) and washer (2) over cable (3).
(c)
Place cable (3) in cylinder end of terminal (4) and crimp.
(d)
Slide shell (1) and washer (2) over terminal (4).
3
1
2
4