TM 9–2350–311–20–2
8–46
Change 2
8–10 NBC GROUND LEAD
This task covers:
a.
Removal
b.
Disassembly/Assembly
c.
Testing
d.
Installation
INITIAL SETUP
Applicable Configuration
M109A4/M109A5 howitzers
Test Equipment
Multimeter (item 6, Appx H)
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
Materials/Parts
Lockwasher (item 55, Appx G)
Lockwasher (item 77, Appx G)
Equipment Condition
Disconnect batteries (TM 9–2350–311–20–1)
a.
Removal
1
Remove cap screw (1), lockwasher (2), and one end of lead (3) from M27 periscope box (4). Discard lock-
washer.
2
Remove cap screw (5), lockwasher (6), and other end of lead (3) from top of M2A2 air purifier (7). Discard
lockwasher.
b.
Disassembly/Assembly
See repair procedures for terminals (para 8–1).
c.
Testing
Using multimeter, test NBC ground lead for continuity.
d.
Installation
1
Secure lead (3) to M27 periscope box (4) using new lockwasher (2) and cap screw (1).
2
Secure lead (3) to M2A2 air purifier (7) using new lockwasher (6) and cap screw (5).
4
1
2
3
5
6
3
7