CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
Clean solenoid valve with rag moistened with cleaning solvent. Clean brackets with cleaning solvent. Dry
components with compressed air.
END OF TASK
TEST AND INSPECTION
1.
Inspect hoses for cuts, tears, kinks, or damage.
2.
Inspect wiring harness for cuts, tears, burns, or damage.
3.
Solenoid Test.
a.
Apply a 24 V dc power supply to the solenoid valve (Figure 4, Item 19) several times and listen for the
solenoid valve to “click" to determine if it functions. If there is no indication of valve movement,
replace unit.
b.
Disconnect power supply from solenoid valve (Figure 4, Item 19).
19
24
Vdc
+
-
MAINT_118
Figure 4.
Air Box Heater Solenoid Test.
END OF TASK
TM 9-2815-205-24
0043
0043-7