DISASSEMBLY - Continued
b.
If necessary, bend two S-hooks (Figure 1, Item 6) open to disconnect chain (Figure 1, Item 5) from oil
filler cap (Figure 1, Item 7) and from strainer element (Figure 1, Item 10).
c.
If necessary, drive strainer element (Figure 1, Item 10) from rocker arm cover (Figure 1, Item 9).
END OF TASK
CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury, illness, or death to
personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
1.
Clean rocker arm covers and breather housings with cleaning solvent and dry with compressed air.
2.
Clean filtering disk with cleaning solvent and dry with compressed air.
END OF TASK
INSPECTION-ACCEPTANCE and REJECTION CRITERIA
Inspect covers for cracks, dents, or other damage.
END OF TASK
ASSEMBLY
1.
On models 5063-5393 and 5063-539L, install oil filler cap (Figure 1, Item 7) as follows:
a.
If removed, press strainer element (Figure 1, Item 10) into oil filler hole from bottom of rocker arm
cover (Figure 1, Item 9) until flush with bottom of bore. Stake strainer element in position.
b.
If removed, connect chain (Figure 1, Item 5) to oil filler cap (Figure 1, Item 7) and to strainer element
(Figure 1, Item 10) with two S-hooks (Figure 1, Item 6). Crimp S-hooks shut.
2.
On model 5063-5392, screw oil filler cap (Figure 1, Item 8) into rocker arm cover (Figure 1, Item 9) until
cap clicks.
TM 9-2815-205-24
0053
0053-3