CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury, illness, or death to
personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
Clean air inlet housing with cleaning solvent and dry with compressed air.
END OF TASK
INSPECTION-ACCEPTANCE and REJECTION CRITERIA
Inspect parts for wear or damage.
END OF TASK
INSTALLATION
NOTE
Angle bracket (Figure 1, Item 2) mounts on right side, third hole from rear of air
inlet housing.
Three air inlet housing screws were removed during removal of fuel line clip and
air pump bracket.
1.
Install new screen (Figure 1, Item 7) (with wire side toward blower), angle bracket (Figure 1, Item 2), air inlet
housing (Figure 1, Item 5), nine new lockwashers (Figure 1, Item 4), and nine screws (Figure 1, Item 3) on
blower (Figure 1, Item 8). Torque screws to 16–20 lb-ft (22–27 N·m).
2.
If removed, install plug (Figure 1, Item 1) and plug (Figure 1, Item 6) in air inlet housing (Figure 1, Item 5).
END OF TASK
TM 9-2815-205-24
0057
0057-3