CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury, illness, or death to
personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
Clean air inlet housing with cleaning solvent and dry with compressed air.
END OF TASK
INSPECTION-ACCEPTANCE and REJECTION CRITERIA
Inspect transducer for damaged wires, connector, and threads.
END OF TASK
INSTALLATION
NOTE
Three air inlet housing screws were removed during removal of fuel line clip and air
pump bracket.
1.
Install new screen (Figure 1, Item 7), air inlet housing (Figure 1, Item 9), nine flat washers (Figure 1, Item 4),
nine new lockwashers (Figure 1, Item 3), two mid-sized screws (Figure 1, Item 1), three long screws
(Figure 1, Item 2), and four short screws (Figure 1, Item 6) on blower (Figure 1, Item 8). Torque screws to
16–20 lb-ft (22–27 N·m).
2.
Install transducer (Figure 1, Item 5) in air inlet housing (Figure 1, Item 9).
END OF TASK
TM 9-2815-205-24
0058
0058-3