TM 9-2815-210-34-2-2
(2)
Cleaning.
FRAME 1
1.
2.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
CAUTION
Do not put hydraulic pump (1) in dry cleaning solvent,
Parts can be damaged and pump will not run properly.
Clean hydraulic pump (1) with dry cleaning solvent. Use a stiff brush to
take off carbon and sludge. Dry with clean cloth.
Clean three elbows (2, 3, and 4) , adapter (5), drive gear (6), pump adapter
(7), two nuts (8), woodruff key (9), and nut (10) in dry cleaning solvent.
Use a stiff brush to take off carbon and sludge. Dry with clean cloth.
END OF TASK
NOTE
PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.
TA 121138
4-371