TM 9-2815-210-34-2-2
FRAME 2
1.
2.
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame.
Keep a fire extinguisher nearby when
solvent is used.
Use only in w en-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
Check that pump adapter (1) and manifold assembly (2) are not cracked,
bent, dented and have no nicks, burrs or scratches on gasket surfaces.
Take out minor nicks, burrs or scratches with a fine mill file or crocus
coth dipped in dry cleaning solvent.
If more repair is needed, get a new
part.
Check that drive gear (3) has no cracks, nicks, burrs, scratches or worn
or chipped gear teeth.
Take out minor nicks, burrs or scratches with a fine
mill file or crocus cloth dipped in dry cleaning solvent. If more repair
is needed, get a new part.
GO TO FRAME 3
NOTE :
CHECK ONLY THOSE PARTS WHICH
ARE CALLED OUT IN THIS FRAME.
PARTS WITHOUT CALLOUTS ARE
SHOWN ONLY FOR REFERENCE
PURPOSES OR ARE CHECKED IN
ANOTHER FRAME.
TA121130