TM 9-2920-257-30&P
Table 2-1.
Generator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Figure 2-1.
Rectifier Mount Ground Test
Step 3.
Check for ground between positive rectifier mount
and generator frame in accordance with figure 2-1.
If ohmmeter reading is less than 50,000 ohms,
replace drive end housing assembly in
accordance with paragraph 3-3 and go to step 8.
2- 3