TM-9-2920-257-30-P

GENERATOR, ALTERNATING CURRENT, 200 AMPERES

TECHNICAL MANUAL; DIRECT SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS

MAY 1987

  TM-9-2920-257-30-P - Page 16 of 111

TM 9-2920-257-30&P
Table 2-1.
Generator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Figure 2-7.
Shorted Printed Circuit Panel Assembly Diode Check.
Step 9.
Check for shorted diodes on printed circuit panel
assembly.
Connect ohmmeter to each of the three
long black leads according to figure 2-7.
If ohmmeter reading is less than 100 ohms,
replace printed circuit panel assembly in
accordance with paragraph 3-3 and go to step 13.
2-9


Back to Top