TM 9-2920-257-30&P
Table 2-1.
Generator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 6.
Figure 2-4.
Shorted Negative Rectifier Test.
Check for shorted negative rectifiers.
Connect
ohmmeter to each of the three negative rectifier
leads in accordance with figure 2-4.
If the ohmmeter reading is less than 100,000
ohms ,
replace drive end housing assembly in
accordance with paragraph 3-3, and go to step 8.
2-6