TM 9-2920-257-30&P
To loosen stator terminal block insulator from inside of drive
end housing, it may be necessary to tap on drive end housing in
an upward direction using a plastic mallet.
(g) Remove drive end housing assembly (21) upward off stator (19)
and terminal block insulator (20),
and place on workbench with rectifiers
facIng upward.
(h) Remove terminal block insulator (20) from stator terminal
studs.
(i) Remove stator (19) from anti-drive end housing (9), and place
on workbench so that winding end turns are not in contact with workbench
surface.
(9) Remove inside seal,
ball bearing, and outer seal from drive end
housing assembly (fig. 3-1).
CAUTION
Care must be taken to ensure that all rectifier leads are inside
housing cavity.
Failure to do so may result in damage to
rectifier leads.
(a) Pack all rectifier leads down inside cavity in drive end
housing assembly (21),
and place housing in arbor press with rectifiers
facing down.
(b) Place ball bearing tool (fig .
F-1) on inside seal according to
figure 3-6 .
Press out inside seal (22), ball bearing (23), and outer
seal (24), all at the same time.
Discard both seals and ball bearing.
3-1 1
NOT E