TM 9-6920-430-14
d.
Using the wrench (7) as shown, carefully turn the desiccant chamber cover (8)
counterclockwise, unscrewing the cover from the chamber.
e.
Withdraw the cover with desiccant cartridge from the chamber and remove used
cartridge.
f.
Examine inner chamber for oil or foreign matter.
NOTE
Oil in outer section of chamber is for lubrication of preformed packing and
is therefore acceptable.
g.
Replace the back-up ring and O-ring (9) on the cover assembly. Apply a light coat
of grease lubricant (Item No. 15, App. E) to O-ring before installation.
3-70
Change 3