TM 9-6920-430-14
Be sure that step c above is performed to vent trapped gas in the flexible hose
before performing the next step.
d.
Carefully disconnect (turning counterclockwise), the hose fitting (5) at the gas
supply bottle adapter (6) using a 3/4-inch wrench to hold and a 9/16-inch-wrench to
loosen. Install the protective plug into the hose fitting.
e.
Unlock the chain and remove from around the gas supply valve (7) housing.
f.
Using a large adjustable wrench, carefully disconnect (turning clockwise) the
supply bottle adapter (6) from the gas supply valve (7).
3-64
Change 3