TM 9-6920-430-14
Table 3-3. GPU Troubleshooting Guidance Chart (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. GPU STARTS BUT PRESSURE GAGE DOES NOT INCREASE
ABOVE 4000 PSIG AND COMPRESSOR CONTINUES TO
OPERATE.
ARE INLET AND OUTLET FITTINGS PROPERLY
SECURED?
SHUT DOWN GPU. IF LEAK CANNOT BE HEARD, CHECK FITTINGS USING LEAK
DETECTING LIQUID. SQUIRT LEAK DETECTING LIQUID AROUND INLET AND
OUTLET HOSE FllTINGS. IF LEAKS ARE DETECTED, CLOSE ARGON GAS SUPPLY
VALVE FULLY CLOCKWISE. OPEN OUTLET BLEED VALVE TO RELIEVE GAS,
THEN CLOSE OUTLET BLEED VALVE FULLY CLOCKWISE. TIGHTEN FITTINGS
IN ACCORDANCE WITH PARA. 3-13 AND 3-14
CAN GAS BE HEARD LEAKING FROM RUPTURE DISC (3)?
IF GAS IS LEAKING FROM RUPTURE DISC, TIGHTEN OR REPLACE RUPTURE DISC
IN ACCORDANCE WITH PARA. 3-23,
IS COMPRESSOR (4) PROPERLY FUNCTIONING?
IF ALL HOSE FITTINGS ARE PROPERLY SECURED AND NO LEAKAGE IS EVIDENT,
COMPRESSOR MAY HAVE LOST PRIME OR THE COMPRESSOR MAY BE FAULTY.
PERFORM THE PRIMING PROCEDURE IN SECTION Vl, BEFORE YOU ATTEMPT TO
REPLACE COMPRESSOR. (SEE PARAGRAPH 3-1 8).
3.1 GPU STARTS BUT OUTLET PRESSURE DOES NOT INCREASE
ABOVE INLET PRESSURE READING.
BOTH PRIME OR FAULTY COMPRESSOR(S), SEE PARA 3-11.1
3-56
Change 3