Table 3-3.
CPU Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-6920-430-14
Guidance Chart (Continued)
IF GPU DOES NOT START WITH AC POWER APPLIED AND THE SAFETY
COVER IS PROPERLY SECURED, THE SAFETY INTERLOCK SWITCH, STARTER
RELAY, OR COMPRESSOR MOTOR MAY BE DEFECTIVE. USING AN
OHMMETER CHECK THE SAFETY INTERLOCK SWITCH FOR CONTINUITY
WITH BUTTON DEPRESSED. IF CONTINUITY IS NOT OBSERVED SWITCH IS
DEFECTIVE.
REPLACE DEFECTIVE SWITCH IN ACCORDANCE WITH PARA. 3-25.
REMOVE ACCESS COVER FROM MOTOR JUNCTION BOX, USING AN AC VOLT-
METER MEASURE MOTOR INPUT VOLTAGE ACROSS BLACK LEADS. IF
VOLTAGE IS NOT MEASURED ACROSS BLACK INPUT LEADS RELAY IS
DEFECTIVE.
REPLACE DEFECTIVE RELAY IN ACCORDANCE WITH PARA. 3-21 (PAGE 3-81).
IF 110 VAC IS MEASURED ACROSS MOTOR INPUT LEADS COMPRESSOR MOTOR
IS DEFECTIVE
REPLACE COMPRESSOR ASSEMBLY IN ACCORDANCE WITH PARA. 3-18
(PAGE 3-76) .
2. GPU FAILS TO STOP WHEN OFF PUSHBUTTON IS DEPRESSED.
IS OFF SWITCH DEFECTIVE?
LIFT SAFETY COVER, IF GPU STOPS OFF SWITCH IS DEFECTIVE.
REPLACE DEFECTIVE OFF SWITCH IN ACCORDANCE WITH PARA. 3-24.