TM-9-6920-430-14

COOLANT RECHARGING UNIT, TRAINING GUIDED MISSILE SYSTEM M80 AND CHARGER, BATTERY PP-7309/T

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

AUGUST 1980

  TM-9-6920-430-14 - Page 120 of 180

TM 9-6920-430-14
Table 3-4. Battery Charger Troubleshooting Guidance Chart
NOTE:
THOSE STEPS MARKED WITH AN ASTERISK (*) SYMBOL
ARE FOR REPAIRS TO BE ACCOMPLISHED AT MTS
LOCATION ONLY. OTHER USERS WILL TURN IN BATTERY
CHARGER THROUGH SUPPLY CHANNELS FOR REPAIR.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. POWER LAMP DOES NOT ILLUMINATE.
IS AC POWER CABLE CONNECTED TO SOURCE?
IF NOT, CONNECT TO AC SOURCE
IS POWER LAMP DEFECTIVE?
REPLACE WITH SPARE LAMP IN LID COVER.
IS OVERLOAD PROTECTION FUSE (DC 1 AMP) FUSE OPEN?
VISUALLY INSPECT FUSE. IF OPEN, REPLACE WITH SPARE FUSE IN PANEL
ASSEMBLY SPARE FUSE HOLDER.
2. ALL CHARGE LAMPS DO NOT ILLUMINATE WITH
SELECTOR SWITCH IN CHARGE POSITION.
PRESS TO TEST
IF LAMP ILLUMINATES IN TEST POSITION, BUT DOES NOT ILLUMINATE IN
CHARGE MODE, THE TEMPERATURE OF BATTERY MAY BE BE LOW 50°F.
LEAVE SWITCH IN CHARGE MODE TO AL LOW SUFFICIENT TIME (UP TO 2 HOURS)
FOR THE HEATER BLANKETS TO WARM BATTERIES IN THE CARRYING CASE.
CHECK BATTERY CARRYING CASE TO ASSURE THAT
BATTERY IS PROPERLY SEATED IN BATTERY COMPARTMENT,
REMOVE AND REINSERT TO ASSURE GOOD TERMINAL CONTACT.
IS BATTERY DEFECTIVE?
REPLACE WITH KNOWN GOOD BATTERY.
IS TOGGLE SWITCH DEFECTIVE?
CHECK TOGGLE SWITCH FOR CONTINUTY. IF DEFECTIVE, REPLACE IN
ACCORDANCE WITH PARA 3-29, PAGE 3-85.
3-60
Change 1
M1416972A


Back to Top