TM-9-6920-430-14

COOLANT RECHARGING UNIT, TRAINING GUIDED MISSILE SYSTEM M80 AND CHARGER, BATTERY PP-7309/T

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL

AUGUST 1980

  TM-9-6920-430-14 - Page 125 of 180

TM 9-6920-430-14
3-13. GAS SUPPLY BOTTLE REPLACEMENT
High gas pressure (up to 6200 psig) exists when performing the procedure
below. Death or severe injury may result if you fail to observe safety
precautions.
a. Close the argon gas supply valve (1) fully clockwise.
b. Check that the INLET SHUTOFF valve (2) is closed fully clockwise.
c. Slowly open the INLET BLEED valve (4) counterclockwise until you hear gas
escaping. After gas has vented, further open the INLET BLEED valve (4) two complete
turns counterclockwise.
Change 1
3-63


Back to Top