TM 9-6920-430-14
NOTE
Element for the top canister is MIS-23455/1-001. Element for the bottom
canister is MIS-23455/1-002.
h.
Replace desiccant cartridge (10). Before installing, examine the plunger assembly
preformed packing (11). If damage to preformed packing is obvious, replace desiccant
cartridge.
i.
Grasping the cartridge with the plastic bag, insert the cartridge into chamber (12)
being careful not to touch the cartridge with your hands.
j.
Immediately install the cover assembly into the chamber, threading it in the
clockwise direction.
k.
Using the wrench (13) as shown, carefully turn the desiccant chamber cover (l4)
clockwise to seal the cover to the chamber.
1.
Repeat steps d through j (page3-70) to replace the other desiccant cartridge.
Change 3
3-71/(3-72 blank)