3-16. DESICCANT REPLACEMENT
During non-operating use, GPU is pressurized at 500 psig with argon gas to
minimize system contamination.
This pressure must be vented before
replacing desiccant cartridge.
a. Insure that the gas supply valve on the supply bottle is closed fully clockwise.
b. Disconnect the power cable from the ac source. Disconnect the gas supply bottle
according to the instructions contained para. 3-13 steps a through d.
When performing the steps below, care must be taken to minimize system
contamination. The area must be free of wind, drafts or dust movement.
c. Insure that INLET BLEED valve (1) is opened (two turns counterclockwise). Open
the OUTLET BLEED valve (2) two complete turns counterclockwise. Very slowly open
the OUTLET SHUTOFF valve (3) and the INLET SHUTOFF valve (4) to relieve all the
gas in the system. The INLET PRESSURE gage (5) and outlet PRESSURE gage (6) must
read 0 psig.