Table 3-4. Battery Charger Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. TEST LAMP DOES NOT ILLUMINATE.
PRESS TO TEST
TM 9-6920-430-14
Guidance Chart (Continued)
IF LAMP DOES NOT ILLUMINATE IN TEST POSITION’ REPLACE LAMP WITH
SPARE IN LID COVER.
4. TEST LAMP ILLUMINATES IN TEST POSITION FOR ALL COMPARTMENTS
BUT ONE
CHECK SUSPECT COMPARTMENT FOR DEFECTIVE BATTERY
REPLACE SUSPECT BATTERY WITH A KNOWN FULLY CHARGED
BATTERY FROM OPPOSITE COMPARTMENT. IF TEST LAMP
ILLUMINATES EITHER CHARGING CIRCUIT OR BATTERY IS
DEFECTIVE, PLACE SUSPECT BATTERY IN ANOTHER CHARGING
COMPARTMENT AND ALLOW BATTERY AMPLE TIME TO CHARGE
(16 HOURS). RETURN BATTERY TO SUSPECT COMPARTMENT AND
REPEAT TEST. IF TEST LAMP ILLUMINATES CHARGING CIRCUIT IS
DEFECTIVE.
REPLACE THE CHARGING CIRCUIT ASSEMBLY CARD IN ACCORDANCE
WITH PARA. 3-28a THROUGH 3-28g, PAGE 3-84.
IF TEST LAMP DOES NOT ILLUMINATE, ORIGINAL SUSPECT BATTERY
WAS DEFECTIVE.
5. HEATER CIRCUITS NOT WORKING.
CHECK AC HEATER 5 AMPERE FUSE.
VISUALLY INSPECT FUSE. IF FUSE IS OPEN, REPLACE WITH SPARE IN FRONT
PANEL ASSEMBLY.
CHECK CABLE CONNECTION AT BATTERY CARRYING
CASE CONNECTOR.
IF CONNECTOR IS LOOSE TIGHTEN UNTIL SNUG TO ASSURE CONTACT
CLOSURE OF SAFETY SWITCH AT CONNECTOR RECEPTACLE.