MALFUNCTION
3-3. GPU Troubleshooting Guidance Chart (Continued)
TEST OR INSPECTION
CORRECTIVE ACTION
5. HIGH SQUEAL OR SQUEAK NOISE IS HEARD WHEN PUMP
IS OPERATING.
CHECK RUNNING TIME METER TO DETERMINE HOW
MANY HOURS HAVE ELAPSED SINCE DRIVE
MECHANISM (6) WAS LAST LUBRICATED.
IF OVER 150 HOURS HAVE ELAPSED SINCE LAST LUBRICATION, SERVICE UNIT
AS FOLLOWS: OPEN REAR ACCESS DOOR FOR ACCESS TO DRIVE MECHANISM
AND USING OIL CAN WITH SAE-10 OIL, SQUIRT OIL ONTO PISTON ROD. IF NOISE
PERSISTS, DRIVE MECHANISM IS DEFECTIVE, SHUT DOWN SYSTEM.
REPLACE COMPRESSOR ASSEMBLY IN ACCORDANCE WITH PARA. 3-18, (PAGE 3-76).
6. COMPRESSOR MOTOR RUNS WHEN ON SWITCH IS
DEPRESSED THEN STOPS WHEN ON SWITCH IS RELEASED.
IS STARTER RELAY REMAINING CLOSED?
USING AN AC VOLTMETER, CHECK VOLTAGE ACROSS STARTER RELAY TERMl-
CONTACTS ARE DEFECTIVE.
REPLACE STARTER RELAY IN ACCORDANCE WITH PAR A. 3-21, (PAGE 3-811.
7. RUNNING TIME METER DOES NOT OPERATE WHEN
COMPRESSOR IS RUNNING.
IS POWER BEING APPLIED TO METER TERMINALS
WHEN COMPRESSOR IS RUNNING?
USING AN AC VOLTMETER, CHECK VOLTAGE ACROSS METER TERMINALS
LABELED M1 AND M2 WITH COMPRESSOR RUNNING. IF 110 VAC IS PRESENT
RUNNING TIME METER IS DEFECTIVE.
REPLACE IN ACCORDANCE WITH PARA. 3-19, (PAGE 3-79).