TM 9-6920-430-14
m.
Close INLET BLEED (16), INLET SHUTOFF (17), OUTLET SHUTOFF (20), and
OUTBLEED (19) valves fully clockwise.
n.
Connect the gas supply bottle and check for leaks around inlet hose per the instructions in
para. 3-13, steps j and k (page 3-65).
o.
Slowly open the INLET SHUTOFF valve (17) counterclockwise until INLET PRESSURE
gage (18) indicates 1000 to 1500 psig; then, close INLET SHUTOFF valve (17) full clockwise. The
OUTLET PRESSURE gage (21) should read the same pressure as the INLET PRESSURE gage
(18). If not, connect the power cable and momentarily press the ON (23) and then the OFF (22)
pushbutton to obtain positive reading on the OUTLET PRESSURE gage (21).
NOTE
If pump does not go on, open left access door and momentarily press the reset
switch. Close access door and again press ON pushbutton.
Change 1
3-73