Installation of Air Conditioning Kit to M1025 and M1025A1 with GSIE Add-on-Armor
(Cont’d).
b. Install Evaporator and Condenser (Cont’d)
Figure 2-129.
Band Clamps
Figure 2-128.
Evaporator Side Brackets
(17)
Remove two top center bolts from rear center armor plate and rear side armor plate.
(18)
Loosely attach evaporator side brackets (23) to evaporator unit with original hardware.
NOTE
For ease of installation, pre-bend ends of band clamps prior to installing on
receiver/drier bracket.
(19)
Install bolts (24) flat washers (25), and oversize washers (26) through evaporator side
brackets (23), armor plates, and receiver/drier bracket, and secure with flat washers (27)
and locknuts (28).
Tighten snug.
(20)
Install band clamps (29) on receiver drier bracket (30).