TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 268 of 534

TM 5-5420-202-20-4
SMOKE GENERATOR SOLENOID REPLACEMENT (Sheet 2 of 5)
1.
2.
3.
4.
5.
6.
7.
Manually disconnect electrical connectors
(A) from solenoids(B).
Using 7/8 inch wrench, disconnect elbow-
to-solenoid hose (C) from 90-degree
elbow (D).
Using 11/16 inch wrench, disconnect
output fuel hose (E) from 45-degree
elbow (F).
Using 7/16 inch wrench to hold screw
and 7/16 inch socket and extension on
nut, remove nut and screw (G) and remove
ground wire (H) from bracket.
Using pliers, cut and remove lockwire
(J). Throw lockwire away.
Using 3/4 inch socket, remove two screws
(K) securing bracket (L) to engine.
Remove bracket (L) and attached sole-
noids (B) with fittings as a unit.
Go on to Sheet 3
21-26
TA248767


Back to Top