TM-5-5420-202-20-4

M60A1 CHASSIS, TRANSPORTING; FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL; VOLUME 4 OF 4

OCTOBER 1985

  TM-5-5420-202-20-4 - Page 275 of 534

TM 5-5420-202-20-4
SMOKE GENERATOR SOLENOID OUTPUT FUEL HOSE REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Using 3/4 inch wrench, install 90-degree elbow (A) to tee (B). Adjust elbow to face
engine.
2.
Position and manually connect hose
(C) to 90-degree elbow (A) and 45-degree
elbow (D).
3.
Using 11/16 inch wrench, tighten hose
(C) connectors to elbows (A) and (D).
WARNING
Do not activate smoke generator in a building or closed area or with personnel near,
CAUTION
Always be aware of wind direction and speed when using smoke generator.
4.
Start engine (TM 5-5420-202-10) and run until normal operating temperatures are attained.
Run engine at 1600 rpm and activate smoke generator. Observe operation. Shut off
smoke generator. Shut down engine.
5.
Check smoke generator lines for leaks. Correct as necessary.
6.
Install engine shroud (page 9-31).
End of Task
TA248774
21-33


Back to Top