INSTALLATION - Continued
6.
Close fresh air shutoff rod (Figure 4, Item 9) before connecting fresh air control cable (Figure 4, Item 2).
7.
Install clip (Figure 4, Item 1) and fresh air control cable (Figure 4, Item 2) on fresh air shutoff rod
(Figure 4, Item 9) with cotter pin (Figure 4, Item 7).
8.
Install fresh air control cable (Figure 4, Item 2) on personnel hot water heater (Figure 4, Item 8) with clamp
bracket (Figure 4, Item 4), spring nut (Figure 4, Item 6), and screw (Figure 4, Item 3).
9.
Adjust air intake flap (Figure 4, Item 10) to the closed position.
1
2
3
4
5
6
7
8
9
10
M5169DAA
Figure 4.
Fresh Air Vent Control Assembly Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
Check fresh air vent for proper operation. (TM 9-2320-272-10)
END OF TASK
END OF WORK PACKAGE
TM 9-2320-272-23-4
0741
0741-4