TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 927 of 1390

TM 9-2320-328-13&P-2
0260-3/(4 blank)
DRAFT
0260
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Connect T2 connector (7) on ground terminal (8) with lockwasher (6) and nut (5).
5.
Connect T1 connector (3) on power terminal (4) with lockwasher (2) and nut (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Install cab instrument panel A (WP 0205)
END OF TASK
END OF WORK PACKAGE
HWT2377


Back to Top