OUTRIGGER CONTROLS FAIL TO OPERATE (CONTINUED)
THAAD0635
NOTE
MRP rack locks must be disengaged to operate outriggers. MRP rack locks are
disengaged when RACK LOCKS ENGAGED indicator light is not illuminated or flashing.
Step 4.
Turn engine start switch ON (
Position LHS cab control mode
select switch to MRP position (WP 0012). Check if RACK LOCKS ENGAGED indicator
light is not illuminated or flashing (WP 0012).
a.
If RACK LOCK ENGAGED indicator light is illuminated or flashing, start
engine (
and disengage MRP rack locks (WP 0012).
b.
If rack locks do not disengage, troubleshoot MRP Locks Do Not
Disengage (WP 0039).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TM 9-2320-347-10)
TM 9-2320-347-10)