5-24
TM 9-2330-227-14&P
WALL RECEPTACLE CABLES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
WARNIN G
Contact with live 110-volt electrical wires could result in serious injury or death. Make
sure power source is disconnected before doing this task.
Cover (1)
Four screws (2)
Using 3/16-inch flat-tip screwdriver,
unscrew and take out.
Circuit
Cover (1)
Lift off.
breaker box (3)
NOT E
Tag wires to aid in installation (page 4-4). To replace wall receptacle cables you must
disconnect subject cable at circuit breaker box. Steps 3 thru 6 disconnect left side
cables. Steps 7 thru 10 disconnect right side cables.
Cable (4), with
Screw (5)
Using 3/16-inch flat-tip screwdriver,
metal band 38S
unscrew part way.
Terminal block (6)
Cable (4)
Pull off.
Cable (7), with
Screw (8)
Using 3/16-inch fiat-tip screwdriver,
metal band 38D
unscrew part way.
Terminal (9)
Cable (7)
Pull off.
Cable (10) with
Screw (11)
Using 3/16-inch flat-tip screwdriver,
metal band 38R
unscrew part way.
Terminal block (6)
Cable(10)
Pull off.
Cable (12) with
Screw (13)
Using 3/16-inch fiat-tip screwdriver,
metal band 38C
unscrew part way.
Terminal (14)
Cable (12)
Pull off.