WALL RECEPTACLE CABLES - CONTINUED
LOCATION
ACTION
ITEM
REMARKs
REPAIR - CONTINUED
22.
New cable (11)
a.
b.
From bulk cable, cut a 2-ft (50.8 mm)
length of cable.
Using wire stripper, strip insulation
back 3/4-inch (19 mm) from each end.
NOT E
The contact screws (3) and (10) differ in color. One is a shiny silvery finish, the other
a flat bronze color. When installing new cable, never connect silver to bronze.
Always connect silver to silver and bronze to bronze.
23.
Contact screws (3)
New cable (11)
and (10)
24.
Cables (1)
and (11)
Contact screws
(3) and (10)
Place in position, and wrap ends around
contact screws.
The undamaged cable will remain in
place. At each contact screw there
will be two cables, the old cable
and new cable.
Tighten using 3/16-inch flat-tip
screwdriver.
5-27