0024-3
TM 9-2330-335-14&P
0024
FEMALE CONNECTOR REPAIR
00024
1.
Slide shell (Figure 2, Item 5) and insulator (Figure 2, Item 6) up wire lead (Figure 2, Item 7) until clear of
terminal (Figure 2, Item 8).
2.
Cut wire lead (Figure 2, Item 7) as close as possible to terminal (Figure 2, Item 8).
3.
Slide insulator (Figure 2, Item 6) and shell (Figure 2, Item 5) off wire lead (Figure 2, Item 7).
4.
Strip insulation from wire lead (Figure 2, Item 7) l/8 in. from end.
5.
Slide shell (Figure 2, Item 5) and insulator (Figure 2, Item 6) on wire lead (Figure 2, Item 7).
6.
Slide wire lead (Figure 2, Item 7) end in terminal (Figure 2, Item 8). Crimp terminal to wire lead. Apply insulating
compound to end of wire lead.
7.
Slide insulator (Figure 2, Item 6) and shell (Figure 2, Item 5) over terminal (Figure 2, Item 8) until seated.
8.
Apply insulating compound to outside of female connector shell (Figure 2, Item 5). Push connector halves together
until seated.
Figure 2.
Female Connector.
024
9.
Connect power. Test semitrailer lights for proper operation.
END OF TASK
447-0049