TM-9-2330-335-14-P

SEMITRAILER, TACTICAL, BREAKBULK/CONTAINER TRANSPORTER, 22-1/2 TON, RESET M871R, M871A1R AND M871A2R

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE MANUAL (INCLUDES REPAIR PARTS AND SPECIAL TOOLS LIST)

SEPTEMBER 2008

  TM-9-2330-335-14-P - Page 166 of 640

TM 9-2330-335-14&P
0028-2
0028
REMOVAL
00028
1.
Remove four self-tapping screws (Figure 1, Item 1) and pull out receptacle converter box (Figure 1, Item 2) from
semitrailer. Discard self-tapping screws.
Figure 1.
Receptacle Converter Box.
028
2.
Disconnect cable (Figure 2, Item 3) from semitrailer wiring harness and remove receptacle converter box
(Figure 2, Item 2) from semitrailer.
3.
Remove cable (Figure 2, Item 3) from receptacle converter box (Figure 2, Item 2).
Figure 2.
Cable.
028
END OF TASK
INSTALLATION
00028
1.
Install cable (Figure 2, Item 3) on receptacle converter box (Figure 2, Item 2).
2.
Connect cable (Figure 2, Item 3) to semitrailer wiring harness and position receptacle converter box (Figure 2, Item 1)
on semitrailer.
3.
Install four new self-tapping screws (Figure 1, Item 1) securing receptacle converter box (Figure 1, Item 2) to semitrailer.
END OF TASK
447-0203
M871R
M871A1R
447-0204


Back to Top