0030-1
TM 9-2330-335-14&P
0030
ORGANIZATIONAL MAINTENANCE
-
WIRING HARNESSES REPLACEMENT
Removal, Installation
WARNING
Disconnect electrical power source before performing any maintenance on the electrical system.
Failure to comply could result in injury to personnel.
CAUTION
Use dielectric grease on all electrical connection(s) and grounds to prevent corrosion. Failure to
comply may result in damage to equipment.
NOTE
See WP 0105 for technical data on ABS/ECU brake system.
INITIAL SETUP
Maintenance Level
0
Organizational
0
Tools and Special Tools
0
Tool kit, general mechanic’s (Item 4, WP 0082)
0
Materials/Parts
0
Grease, dielectric (silicone) (Item 7, WP 0085)
0
References
0
Electrical schematic (WP 0023)
0
WP 0029
0
References - Continued
0
WP 0041
0
WP 0105
0
Equipment Conditions
0
Landing legs down
0
Semitrailer disconnected from prime mover
0
Electrical power disconnected from semitrailer
0
Tires chocked
0
Ground boards emplaced
0
4