0029-1
TM 9-2330-335-14&P
0029
ORGANIZATIONAL MAINTENANCE
-
RECEPTACLE CONVERTER BOX AND NOSE PLATE REPLACEMENT (M871A2R)
Removal, Installation
WARNING
Disconnect electrical power source before performing any maintenance on the electrical system.
Failure to comply could result in injury to personnel.
CAUTION
The semitrailer’s converter box and electrical system will be damaged if the 12V (7 pin) and 24V
(12 pin) cables are plugged in at the same time. Do not plug both the 12V (7 pin) and 24V (12 pin)
cables in at the same time. Failure to comply may result in equipment damage.
NOTE
See WP 0089 for technical data on the receptacle converter box.
INITIAL SETUP
Maintenance Level
0
Organizational
0
Tools and Special Tools
0
Tool kit, general mechanic’s (Item 4, WP 0082)
0
Materials/Parts
0
Grease, dielectric (silicone) (Item 7, WP 0085)
0
Locknut (4)
0
Screw, self-tapping (6)
0
References
0
Electrical schematic (WP 0023)
0
WP 0089
0
Equipment Conditions
0
Landing legs down
0
Semitrailer disconnected from prime mover
0
Tires chocked
0
Ground boards emplaced
0
4