TM 9-2330-335-14&P
0024-4
0024
TERMINAL REPLACEMENT
00024
NOTE
This procedure is typical for ring-type and quick-disconnect terminals. Procedure shown is for ring
(grounding) terminal.
1.
Cut wire lead (Figure 3, Item 9) as close as possible to terminal (Figure 3, Item 10). Discard terminal.
2.
Strip insulation from wire lead (Figure 3, Item 9) equal to depth of new terminal (Figure 3, Item 10).
3.
Slide wire lead (Figure 3, Item 9) end in new terminal (Figure 3, Item 10). Crimp terminal to wire lead.
4.
Connect terminal.
5.
Connect power. Test semitrailer lights for proper operation.
Figure 3.
Terminal.
024
END OF TASK
CIRCUIT MARKER BAND REPLACEMENT
00024
1.
Using flat-tip screwdriver, open tab ends (Figure 4, Item 11) on marker band (Figure 4, Item 12). Remove from
wire lead (Figure 4, Item 13), note circuit number, and discard marker band.
2.
Etch proper number on new marker band (Figure 4, Item 12).
3.
Place new circuit marker band (Figure 4, Item 12) on wire lead (Figure 4, Item 13). Bend tab ends (Figure 4, Item 11) over
wire lead.
Figure 4.
Circuit Marker Band.
024
4.
Connect power.
END OF TASK
END OF WORK PACKAGE
447-0050
447-0051