Table
1.
FIELD LEVEL PMCS - SEMI-ANNUAL - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
NOTE
•
If an air-operated grease gun does
not purge the fitting, use a hand-
operated grease gun. If the part does
not purge, remove fitting and clean,
install fitting and grease again. If part
still does not purge, refer to
maintenance task for that
component.
•
When using a grease gun, apply
lubricant to the fitting until clean
lubricant squeezes out of the part
being lubricated.
LUBRICATE EIGHT FITTINGS
TURNTABLE BEARING
Figure 5.
Field Level PMCS Semi-Annual.
b. Lubricate the turntable bearing with GAA (WP
0193,
Table 1, Item 33, 34, 35, 36, 37) every 3,000 mi (4,828
km) or semi-annually whichever comes first.
Fittings will not purge old
lubricant out of
component.
TM 9-2330-342-23&P
0047
0047-4