TM 9-2350-238-20-1
2-97. MAINTENANCE OF BULKHEAD TO BULKHEAD GENERATOR CIRCUIT
ELECTRICAL LEAD.
This task covers:
a.
Removal
d.
Reassembly
b.
Disassembly
e. Installation
c. Inspection/Repair
INITIAL SETUP
Materials/Parts
Electrical wire (figure D-2, appx D)
Gasket
References
TM 9-2350-238-24P-1
Equipment Conditions
2-840
Batteries disconnected
2-952 Driver's seat removed
2-928 Driver's compartment forward cowl
removed
2-928
Driver’s compartment aft cowl
removed
General Safety Instructions
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
1
2
3
4
5
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Wiring harnesses and leads are secured
to the hull and components with loop
clamps, straps, clips, ground screws, etc.
Remove only the hardware which secures
the wiring harness or lead being removed.
Tag and disconnect plug connector (1)
from voltage regulator.
Remove four screws (2) and four washers
(3), and tag and disconnect receptacle
connector
(4)
from front bulkhead recep-
tacle.
If damaged, remove gasket (5) from receptacle
Remove bulkhead to bulkhead generator circuit
connector (4).
electrical lead (6) from hull through driver’s
compartment.
2-672