TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 694 of 1364

TM 9-2350-238-20-1
2-95. MAINTENANCE OF BULKHEAD DISCONNECT TO GENERATOR ARMATURE
ELECTRICAL LEAD.
This task covers:
a.
Removal
d.
Reassembly
b.
Disassembly
e. Installation
c. inspection/Repair
INITIAL SETUP
Materials/Parts
General Safety Instructions
Electrical wire (figure D-2, appx D)
Insulation sleeving (figure D-1, appx D)
References
Failure to remove or disconnect
TM 9-2350-238-24P-1
batteries before removing or installing
any electrical wiring harness or lead
Equipment Conditions
may result in injury or damaged
2-640 Batteries disconnected
equipment.
2-384 Powerplant removed
2-766 Auxiliary drive removed
REMOVAL
1
2
3
4
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Wiring harnesses and leads are secured
to the hull and components with loop
clamps, straps, clips, ground screws, etc.
Remove only the hardware which secures
the wiring harness or lead being removed.
Tag and disconnect plug connector (1)
from voltage regulator.
Tag and disconnect cable terminal (2)
from generator armature, terminal B.
Remove bulkhead disconnect to generator
armature electrical lead (3) from hull.
2-668


Back to Top