2-94. MAINTENANCE OF BATTERY TO CIRCUIT BREAKER ELECTRICAL LEAD.
This task covers:
a.
Removal
b.
Inspection/Repair
c. Installation
INITIAL SETUP
Materials/Parts
Electrical wire (figure D-2, appx D)
Insulation sleeving (figure D-22, appx D)
References
TM 9-2350-238-24P-1
Equipment Conditions
2-840
Batteries disconnected
2-918 Hull access cover removed
General Safety Instructions
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
REMOVAL
1
2
3
4
5
Failure to remove or disconnect
batteries before removing or installing
any electrical wiring harness or lead
may result in injury or damaged
equipment.
Open battery access cover (1).
Wiring harnesses and leads are secured
to the hull and components with loop
clamps, straps, clips, ground screws, etc.
Remove only the hardware which secures
the wiring harness or lead being removed.
Disconnect cable terminal (2) from battery
terminal (3).
Disconnect shell connector (4) from circuit
breaker.
Remove battery to circuit breaker electrical
lead (5) from hull.