TM-9-2350-238-20-1

HULL AND RELATED COMPONENTS RECOVERY VEHICLE, FULL TRACKED: LIGHT, ARMORED, M578

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL

MAY 1994

  TM-9-2350-238-20-1 - Page 730 of 1364

TM 9-2350-238-20-1
2
Open air cleaner blower motor access
door (1).
Failure to remove or disconnect
batteries before removing or installing
3
Tag and disconnect shell connector (2)
any electrical wiring harness or lead
from forward air cleaner centrifugal fan.
may result in injury or damaged
equipment.
4
Tag and disconnect shell connector (3)
from line connection disconnect.
1
Wiring harnesses and leads are secured to
the hull and components with loop clamps,
5
Remove disconnect to forward
straps, clips, ground screws, etc. Remove
blower motor electrical lead (4)
only the hardware which secures the
through driver’s compartment.
wiring harness or lead being removed.
air cleaner
from hull
1
Inspect for broken, damaged, or missing
parts.
2
If damaged or missing, replace marker
bands. Etch or stamp lead number on
new band.
3
For repair of shell connectors, refer to
general maintenance, page 2-371.
4
Electrical wire is a manufactured item,
refer to appendix D.
5
Repair is by replacement of authorized
parts (TM 9-2350-238-24P-1).
2-704