TM 9-2350-260-20-1-2
FUEL-WATER SEPARATOR CONTROL ASSEMBLY REPLACEMENT (2D ENGINE) (Sheet 8 of 8)
3.
Set MASTER CONTROL switch to ON (TM 9-
2350-260-10).
Watch fuel-water separator bleed
cap (A) for air release (bubbles).
4.
Set MASTER CONTROL switch to OFF (TM 9-
2350-260-10).
After about one minute, repeat
step 3.
NOTE
It may be necessary to perform steps
4 and 5 several times until a constant
fuel flow (no bubbles) from the bleed
cap (A) is observed.
5.
Check for leaks and tighten or replace component as necessary.
6.
Using 7/16 inch wrench, turn fuel-water separator bleed cap (A) to the right until snug.
7.
Perform operational check of automatic drain (page 7-245).
8.
Set FUEL PUMPS switch to OFF (TM 9-2350-260-10).
9.
Set MASTER CONTROL switch to OFF (TM 9-2350-260-10).
10.
Disconnect engine from powerplant ground hop (page 5-67).
11.
Install powerplant (page 5-40).
End of Task
TA148370
7-295