TM-9-2350-260-20-1-3

TANK, COMBAT, FULL TRACKED 105-MM GUN, M60 2350-00-678-5773 (HULL)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE VOLUME 3 OF 4 CHAPTERS 10 THRU 15

  TM-9-2350-260-20-1-3 - Page 464 of 783

TM 9-2350-260-20-1-3
SHIFTING CONTROL CONNECTING LINK REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Using 9/16 inch wrench, install nuts (B) and (C) onto rod (A).
2.
Using 9/16 inch wrench, install rod ends (D) and (E) onto rod (A).
3.
Position rod assembly (A) into links (F) and (G) and, using 9/16 inch socket and ratchet, install screws (H) and (J)
through links (F) and (G) and rod ends (D) and (E).
4.
Adjust shifting linkage (page 11-2).
End of Task
TA146587
11-33