TM 9-2350-261-20-2
REMOVE/INSTALL BATTERY LEADS (M577A2 ONLY)
0299 00
THIS WORK PACKAGE COVERS:
Removal (page 0299 00-1).
Clean, Inspect, and Repair (page 0299 00-2).
Installation (page 0299 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Battery Terminal Cleaner (WP 0780 00, Item 12)
Battery Terminal Puller (WP 0780 00, Item 47)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Grease (WP 0782 00, Item 24)
Sod ium
b
icarbon ate (W P 07 82 00 , Item 70 )
Grommet (3)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Battery access cover removed (WP 0297 00)
REMOVAL
WARNING
Gas from batteries can explode. Ventilate compartment before you disconnect or connect
battery cables. Battery acid can burn or blind you. Do not get acid on your skin or eyes.
ALWAYS disconnect ground lead (circuit 7) first and connect it last.
WARNING
Electrical current can burn you. Disconnect battery ground lead before you start task.
CAUTION
Do not start carriers without batteries installed. Starting engine with outside power will cause
damage to electrical components in the regulator.
029900-1