TM 9-2350-261-20-2
REPLACE FAN DRIVE FIXED IDLER AND PULLEY
0212 00
THIS WORK PACKAGE COVERS:
Removal (page 0212 00-1).
Installation (page 0212 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Snap Ring Pliers (WP 0780 00, Item 45)
Torque Wrench (WP 0780 00, Item 104)
Materials/Parts
Cotter pin (2)
Personnel Required
Unit Mechanic
References
W P 02 11 00
Equipment Condition
Engine stopped/shutdown (see your -10)
Ramp lowered (see your -10)
Power plant rear access panel removed (WP 0431 00,
WP 0432 00, or WP 0433 00)
REMOVAL
1.
Remove fan drive belts (WP 0211 00).
2.
Remove bolt (1), washer (2), nut (3), and idler pulley (4) from idler arm (5).
3.
Remove two cotter pins (6), straight pins (7) and (8), and idler arm (5) from transfer gearcase. Discard cotter pins.
4.
Remove two retaining rings (9), bearings (10), and spacer (11) from idler pulley (4).