TM 9-2520-270-34
WARNING
Do not handle hot or cold
parts without protective
gloves.
Personnel can be
a.
b.
c.
Using oven, heat housing assembly (2)
to 150° F (66° C).
Use gloves to hold housing
assembly (2). Using mechanical puller
through front of housing assembly,
remove and discard cup (1).
Discard cone and rollers removed in
step 8 if not already discarded.
29. REMOVE CUP (3).
a.
b.
c.
Using oven, heat housing assembly (2)
to 150° F (66° C).
Use gloves to hold housing
assembly (2). Using mechanical puller
through rear of housing assembly,
remove and discard cup (3).
Discard cone and rollers removed in
step 17 if not already discarded.
28. INSPECT INNER ROLLER CUP (3).
a. Inspect cup (3) for damage. See
TM 9-214.
b. If cup (3) is damaged or cone and
rollers were discarded in step 17, cup
must also be discarded. Go to step 29.
If cup is not damaged, go to step 31.
30. CHECK HOUSING ASSEMBLY (2).
a. Let housing assembly (2) return to
room temperature.
b. Using micrometer caliper set and
telescoping gage set, measure inside
diameter of bore (4). Replace housing
assembly (2) if measurement is more
than 3.8417 inches (97.579 mm).
c. Using micrometer caliper set and
telescoping gage set, measure inside
diameter of bore (5). Replace housing
assembly (2) if measurement is more
than 5.5930 inches (142.062 mm).
GO TO NEXT PAGE
Change
1
4-131
27. REMOVE CUP (1).
WARNING
Do not handle hot or cold
parts without protective
gloves. Personnel can be
injured.