TM-9-2815-205-24

6V53/6V53T ENGINES, DIESEL WITH CONTAINERS; MODEL 5063-5299, MODEL 5063-5392, MODEL 5063-5393 AND MODEL 5063-539L

TECHNICAL MANUAL; FIELD AND SUSTAINMENT MAINTENANCE

FEBRUARY 2013

  TM-9-2815-205-24 - Page 257 of 856

CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury or death to personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
Clean fuel solenoid valve with rag moistened with cleaning solvent. Clean brackets with cleaning solvent.
Dry components with compressed air.
END OF TASK
TEST AND INSPECTION
1.
Inspect hoses for cuts, tears, kinks, or damage.
2.
Inspect wiring harness for cuts, tears, burns, or damage.
3.
Test solenoid.
a.
Apply a 24 V dc power source to solenoid valve (Figure 5, Item 2) and listen for valve to “click" to
confirm if valve is opening and closing as power is applied. If no indication of movement is present,
replace solenoid valve.
b.
Disconnect power source from solenoid valve (Figure 5, Item 2).
2
24
Vdc
+
-
MAINT_110
Figure 5.
Air Box Solenoid Test.
END OF TASK
TM 9-2815-205-24
0042
0042-5


Back to Top