CLEANING
WARNING
Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using
cleaning solvent. Failure to comply may result in injury, illness, or death to
personnel.
Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use
only with protective equipment (goggles, face shield, gloves, etc.). Failure to
comply may result in injury to personnel.
Clean flywheel housing with cleaning solvent and dry with compressed air.
END OF TASK
INSPECTION-ACCEPTANCE AND REJECTION CRITERIA
Inspect flywheel housing for cracks or damage.
END OF TASK
INSTALLATION
1.
On models 5063-5393 and 5063-539L, install elbow (Figure 2, Item 32) in left side of flywheel housing
(Figure 2, Item 24).
2.
If removed, install dowel (Figure 2, Item 27) in upper part of flywheel housing (Figure 2, Item 24).
3.
Install new gasket (Figure 2, Item 31), cover (Figure 2, Item 30), three new lockwashers (Figure 2, Item 29),
and three bolts (Figure 2, Item 28) on left side of flywheel housing (Figure 2, Item 24).
Torque bolts to 13–17 lb-ft (18–23 N·m).
TM 9-2815-205-24
0088
0088-5